+
  • c80166c8133093fa04087ae91537fe3b_medium.jpg

Hanging dry powder fire extinguisher


Price:

$

Item No.:WFHEE002 Capacity(Kg):4KG Out-Diameter(Mm):194 Volume:5L Effective Discharging Time (S):≥5 Effective Discharging Range(M):≥3 Operating Temperature(℃):-20~55 Working Pressure(MPa):1.4 Test Pressure(MPa):2.5

Keywords:

Detailed introduction

 

We are an active manufacture, supplier, exporter of premium quality Automatic Fire Extinguisher. This extinguisher is made of a hand-held cylindrical pressure vessel comprising an agent that can be discharged to combat fire at any point of time. This type of extinguisher is best suited to control any kind of fire containing flammable gases or flammable liquid petroleum products. It also works rapidly and effectively against fire of plastics and electrical items. Apart from this, we provide this quality certified Automatic Fire Extinguisher in several capacities as per the requirements of patrons.

 

 

Features:

• Efficient performance

• Robust construction

• Quick results

• Easy to use

Application Areas:

• Commercial areas

• Large warehousing unit

• Manufacturing mills

 

Specifications: 4kg 6kg 8kg 10kg 12kg
Capacity(kg): 4±0.05 6±0.06 8±0.06 10±0.08 12±0.08
Out-diameter(mm): 194 292 306 306 370
Volume: 5L 7.6L 10L 12L 15L
Effective discharging time (s): 5 8 8 9 12
Effective discharging range(m): 3 3 3 3.5 3.5
Operating Temperature(℃): -20~55 -20~55 -20~55 -20~55 -20~55
Class rating: 21A,113B 27A,183B 34A,183B 34A,233B 43A,233B
Working pressure(MPa): 1.4 1.4 1.4 1.4 1.4
Test pressure(MPa):  2.5 2.5 2.5 2.5 2.5
G.W.(kg): 7 9.5 12.5 15 18

 

Note:

1.The suspension point of the fire extinguishing device shall be chosen to be the most prone to fire in the protected area, or above the protected object, the height of which shall be more than one meter above the object to be protected, but not more than three meters.

2.Fire extinguishing device are pressure contained, should avoid collision while transport and storage. The device storage location should be dry and ventilated, preventing from frozen,damp and avoiding rain and burst.

3.When the user sets up the fire extinguishing device, it should be checked at intervals of one quarter. Once the pressure indicator is not in the green area or used, device should be sent for professional maintenance.

4. After re-filled or tested every 5 years,the fire extinguishing device shall be tested by the pressure of 2.1Mpa before continue to use.

 

Please don't hesitate to send us inquiry if we could be of any help.

Send Inquiry

Note: Please leave your email, our professional person will contact you asap!