    The American Hose Rack Assembly (Hose Station) is a one-person operable indoor fire-fighting system designed for controlling incipient-stage fires in buildings. It complies with NFPA 14 standards for Class II and Class III fire service, integrating core components to enable quick fire response.

    Nozzle:Jet/Spray Nozzle
    Hose Valve Size:1.5"/2.5"
    Hose Valve Type:Angle Hose Valve
    Hose Valve Material :Copper Alloy
    Nipple Material :Copper Alloy
    MOQ:50Pieces
    Delivery Time:15-30 Days

    Email:Jony@jyfire.com.cn


    Details Description


    As a dedicated indoor fire-fighting solution, the American Hose Rack Assembly (Hose Station) is engineered for easy, one-person operation—allowing on-site personnel to quickly intervene and control small, incipient fires before they escalate. It strictly adheres to NFPA 14 standards, covering both Class II and Class III fire service requirements, making it suitable for installation in commercial buildings, high-rises, and industrial facilities where rapid indoor fire suppression is critical.

    The assembly consists of 5 core components, ensuring complete functionality: 1) Hose angle valve (controls water flow to the system), 2) Adjustable fog nozzle (delivers flexible water streams for different fire scenarios), 3) Pin rack (neatly stores the fire hose for easy access), 4) Fire hose with NH coupling (securely connects to the water supply and nozzle), and 5) Rack nipple (links the valve to the hose rack). Typically installed in fire cabinets on each floor of a building, it keeps fire-fighting tools organized and readily accessible, eliminating delays in emergency response.

     

    To meet diverse on-site needs, the assembly offers optional components such as pressure reducing valves (PRV), valve escutcheon plates, and fire cabinets (standard or fire-rated). This flexibility ensures compatibility with different building fire protection systems, while all components undergo strict quality checks to guarantee reliable performance in emergencies.

     

     

    Feature


    • One-Person Operation: Designed for easy solo use, enabling quick fire response without additional manpower.
    • NFPA 14 Compliance: Meets NFPA 14 standards for Class II and Class III fire service, ensuring regulatory compliance.
    • Integrated 5-Core Components: Includes hose angle valve, adjustable fog nozzle, pin rack, NH-coupled fire hose, and rack nipple—no extra assembly required.
    • Floor-Wide Installation: Typically mounted in fire cabinets on each building floor, ensuring accessible fire protection across all areas.
    • Optional Component Flexibility: Offers optional PRVs, valve escutcheon plates, and fire cabinets to match specific building needs.
    • Durable & Reliable: All components are built with fire-fighting-grade materials, ensuring stability and longevity in indoor environments.

    Product Parameter


    TypeStandard assemblyOptional components
    1-1/2'' fire hose rack assembly for Class ⅡHose angle vavle,1-1/2'',UL/FMPRV, 1-1/2″, UL/FM
    Hose rack(pink rack),1-1/2'',UL/FMValve escutcheon plate,1-1/2'',ISO
    Rack nipple,1-1/2'',ISOFire cabinet, standard of fire rated,ISO
    Fire hose with NH coupling,100',1-1/2'',UL/FM 
    Adjustable fog nozzle,1-1/2'' 
    2-1/2'' * 1-1/2'' fire hose rack assembly for Class ⅢHose angle valve,2-1/2'',UL/FMPRV,2-1/2'',UL/FM
    Hose rack(pin rack),2-1/2'',UL/FMValve escutcheon plate,2-1/2'',ISO
    Rack nipple,2-1/2'',ISOFire cabinet,standard of fire rated,ISO
    Fire hose with NH coupling,100'1-1/2'',UL/FM 
    Adjustalbe fog nozzle,1-1/2'',UL/FM 
    Reducer(Adapter),2-1/2''*1-1/2'',ISO 

    FAQ


    Q: What’s the difference between Class II and Class III versions of this assembly?

    A: The Class II version (1-1/2″) is designed for smaller fire scenarios with moderate water flow needs; the Class III version (2-1/2″ x 1-1/2″) includes a reducer, supporting higher water flow for larger incipient fires, making it suitable for spaces with higher fire risks.

     

    Q: Why choose us?

    A: With over 20 years of experience in the fire protection industry, our company has professional technical personnel and many well-known partners in the domestic market. We offer favorable prices and guarantee quality—each American Hose Rack Assembly complies with NFPA 14 standards, undergoes strict testing, and uses ISO-certified components to ensure reliable fire suppression performance.

    Contact us
    Act now—stop fire risks at the source!

    JINYUAN TECHNOLOGY DEVELOPMENT CO.,LTD

    Tel.:86-18159244550   Mobil:18159244550

    EMAIL:Jony@jyfire.com.cn

    ADD:CHENGGONG TECHNOLOGY ZONE PHASE 3,XIMEI TOWN,NAN'AN QUANZHOU CITY



    Enquire Now

    For any request of information or technical support, fill in the form. All fields marked with an asterisk* are required.

    Submit Message
    %{tishi_zhanwei}%

    What Are You Looking For?

    全部
    • 全部
    • 产品管理
    • 新闻资讯

    LEAVE A MESSAGE

    For any request of information or technical support, fill in the form. All fields marked with an asterisk* are required.

    Sumbit